A Non-Invasive, Soft Robotic Wearable Glove to Attenuate Hand Tremors
DOI:
https://doi.org/10.47611/jsrhs.v11i3.3814Keywords:
soft robotics, hand tremor, wearable technologyAbstract
Hand tremors are a widespread medical condition that decreases a patient’s quality of life. Due to uncontrollable hand shaking, patients have difficulty completing essential daily tasks. Many also experience embarrassment and anxiety in social settings, which negatively affects many areas of their lives. Current treatments are often invasive, ineffective, and have unwanted side effects. Some non-invasive solutions excessively limit hand motion, making them ineffective in helping the wearer complete tasks, while others are highly visible and bulky. This paper presents a minimalistic, non-invasive, wearable glove that uses active feedback control and miniature, soft robotic pneumatic actuators to attenuate hand tremors while allowing freedom of movement in other directions. We 3D-modelled the hand and wrist and designed our glove and actuators using Fusion 360. These models were imported into Matlab and Simulink, where we simulated the hand tremor, actuation, and control system using spatial contact forces. To actively reduce the tremor amplitude, we used an accelerometer to detect the onset of tremor motion and create a real-time estimate of the hand’s position. This estimate drove a closed-loop PI controller that produced force commands for the pneumatic actuators, which applied a counterforce opposing the direction of hand motion. Based on our simulation results, our active glove control system design successfully reduced the hand tremor amplitude by 75%, from a baseline of ±8.0mm to a significantly improved amplitude of ±2.0mm. These results indicate that our proposed solution could effectively attenuate hand tremors to a level that would increase the wearer’s quality of life.
Downloads
References or Bibliography
Bickel, C. S., Gregory, C. M., & Dean, J. C. (2011). Motor unit recruitment during neuromuscular electrical stimulation: A critical appraisal. European Journal of Applied Physiology, 111(10), 2399. https://doi.org/10.1007/s00421-011-2128-4
Daneault, J.-F., Carignan, B., Rahimi, F., Sadikot, A., & Duval, C. (2013). Postural tremors. https://doi.org/10.1007/978-1-4614-4027-78
Deuschl, G., Raethjen, J., Hellriegel, H., & Elble, R. (2011). Treatment of patients with essential tremor. The Lancet Neurology, 10(2), 148–161. https://doi.org/10.1016/S1474-4422(10)70322-7
Diaz, N. L., & Louis, E. D. (2010). Survey of medication usage patterns among essential tremor patients: Movement disorder specialists vs. general neurologists. Parkinsonism Related Disorders, 16(9), 604–607. https://doi.org/https://doi.org/10.1016/j.parkreldis.2010.07.011
Elble, R. J. (2013). What is essential tremor? Current Neurology and Neuroscience Reports, 13. https://doi.org/10.1007/s11910-013-0353-4
Heusinkveld, L. E., Hacker, M. L., Turchan, M., Davis, T. L., & Charles, D. (2018). Impact of tremor on patients with early stage parkinson’s disease. Frontiers in Neurology, 9. https://doi.org/10.3389/fneur.2018.00628
Hua, S. E., Lenz, F. A., Zirh, T. A., Reich, S. G., & Dougherty, P. M. (1998a). The role of the thalamus and basal ganglia in parkinsonian tremor. Movement Disorders Society, 13, 40– 42. https://doi.org/10.1002/mds.870131307
Hua, S. E., Lenz, F. A., Zirh, T. A., Reich, S. G., & Dougherty, P. M. (1998b). Thalamic neuronal activity correlated with essential tremor. Journal of Neurology, Neurosurgery & Psychiatry, 64(2), 273–276. https://doi.org/10.1136/jnnp.64.2.273
Isaacson, S. H., Peckham, E., Tse, W., Waln, O., Way, C., Petrossian, M. T., Dahodwala, N.,
Soileau, M. J., Lew, M., Dietiker, C., Luthra, N., Agarwal, P., Dhall, R., Morgan, J., Calakos, N., Zesiewicz, T. A., Shamim, E. A., Kumar, R., LeWitt, P., & Pahwa, R. (2020). Prospective home-use study on non-invasive neuromodulation therapy for essential tremor [PMC7427656[pmcid]]. Tremor and other hyperkinetic movements (New York, N.Y.), 10, 29–29. https://doi.org/10.5334/tohm.59
Islam, S., Ahmed, M. S., Arifuzzaman, A., Islam, A., & Akter, S. (2019). Relationship in between strength and polyester content percentage of cotton polyester blended woven fabrics. Int. J. Clothing Sci, 6(1), 1–6.
Javidan, M., Elek, J., & Prochazka, A. (1992). Attenuation of pathological tremors by functional electrical stimulation ii: Clinical evaluation. Annals of Biomedical Engineering, 20(2), 225– 236. https://doi.org/10.1007/BF02368522
Kalaiarasi, L. A., A.; Kumar. (2018). Sensor based portable tremor suppression device for stroke patients. Acupuncture Electro-Therapeutics Research, 43(1), 29–37. https://doi.org/10.3727/036012918X15202760634923
Kaye, R., & Konz, S. (1986). Volume and surface area of the hand. Proceedings of the Human Factors Society Annual Meeting, 30(4), 382–384. https://doi.org/10.1177/154193128603000417
Kim, M.-R., Yun, J. Y., Jeon, B., Lim, Y. H., Kim, K. R., Yang, H.-J., & Paek, S. H. (2016). Patients’ reluctance to undergo deep brain stimulation for parkinson’s disease. Parkinsonism Related Disorders, 23, 91–94. https://doi.org/https://doi.org/10.1016/j.parkreldis.2015.11.010
Louis, E. D. (2009). Essential Tremors: A Family of Neurodegenerative Disorders? Archives of Neurology, 66(10), 1202–1208. https://doi.org/10.1001/archneurol.2009.217
Manto, M., Rocon, E., Pons, J., Belda, J. M., & Camut, S. (2007). Evaluation of a wearable orthosis and an associated algorithm for tremor suppression. Physiological Measurement, 28(4), 415– 425. https://doi.org/10.1088/0967-3334/28/4/007
Mo, J., & Priefer, R. (2021). Medical devices for tremor suppression: Current status and future directions [bios11040099[PII]]. Biosensors, 11(4), 99. https://doi.org/10.3390/bios11040099
Ozdemir, H. (2017). Thermal comfort properties of clothing fabrics woven with polyester/cotton blend yarns. Autex Research Journal, 17(2), 135–141.
Peripheral nervous system. (n.d.). Neurolo-GE. https://sites.google.com/site/ericgestir/neurology
Popovifá Maneski, L., Jorgovanovifá, N., Ilifá, V., Do°en, S., Keller, T., Popovifá, M. B., & Popovifá, D. B. (2011). Electrical stimulation for the suppression of pathological tremor. Medical & Biological Engineering & Computing, 49(10), 1187. https://doi.org/10.1007/s11517-011-0803-6
Rudraraju, N., Sreekanth. (2018). Wearable tremor reduction device (trd) for human hands and arms [V001T10A010], 2018 Design of Medical Devices Conference. https://doi.org/10.1115/DMD2018-6918
Rus, D., & Tolley, M. T. (2015). Design, Fabrication and Control of Soft Robots. Nature, 521(7553), 467–475. http://dx.doi.org/10.1038/nature14543
Shalash, A. S., Mohamed, H., Mansour, A. H., Elkady, A., Elrassas, H., Hamid, E., Elbalkimy, M. H. (2019). Clinical profile of non-motor symptoms in patients with essential tremor: Impact on quality of life and age-related differences. Tremor and other hyperkinetic movements. https://doi.org/10.7916/tohm.v0.736
Taheri, B., Case, D., & Richer, E. (2015). Adaptive suppression of severe pathological tremor by torque estimation method. IEEE/ASME Transactions on Mechatronics, 20(2), 717–727. https://doi.org/10.1109/TMECH.2014.2317948
Zamanian, A. H., & Richer, E. (2017). Adaptive disturbance rejection controller for pathological tremor suppression with permanent magnet linear motor [V001T37A003], Volume 1: Aerospace Applications; Advances in Control Design Methods; Bio Engineering Applications; Advances in Non-Linear Control; Adaptive and Intelligent Systems Control; Advances in Wind Energy Systems; Advances in Robotics; Assistive and Rehabilitation Robotics; Biomedical and Neural Systems Modeling, Diagnostics, and Control; Bio-Mechatronics and Physical Human Robot; Advanced Driver Assistance Systems and Autonomous Vehicles;
Automotive Systems. https://doi.org/10.1115/DSCC2017-5151
Published
How to Cite
Issue
Section
Copyright (c) 2022 Kayla Youhanaie; Ryman Hashem
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Copyright holder(s) granted JSR a perpetual, non-exclusive license to distriute & display this article.